HVAC superheat and subcooling worksheet

Calculate both temperature differences from four measured line and saturation temperatures.

This tool is archived. Recheck its method and dated data before use.

01Enter your values

Runs in your browser

Runs offline in your browser. Once the page and required files have loaded, processing needs no internet.

Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature. No refrigerant lookup or charge diagnosis is made.

Example
°
°
°
°

How it works

Calculate both temperature differences from four measured line and saturation temperatures.

superheat = suction-line temperature − suction saturation temperature; subcooling = liquid saturation temperature − liquid-line temperature

Runs in your browser

Discovery source

Your data stays yours

Inputs are processed on this page and are never sent to a server.

About this tool

Calculate both temperature differences from four measured line and saturation temperatures.

Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature. No refrigerant lookup or charge diagnosis is made.

Use tool ↑
How to use it
  1. Enter your values
    • °C / °F
    • Tsl
    • Tssat
    • Tlsat
    • Tll
  2. Calculation method

    superheat = suction-line temperature − suction saturation temperature; subcooling = liquid saturation temperature − liquid-line temperature

  3. Example scenario · Result

    SH: 7 K; SC: 7 K

Calculation method

  1. Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature.
  2. No refrigerant lookup or charge diagnosis is made.
superheat = suction-line temperature − suction saturation temperature; subcooling = liquid saturation temperature − liquid-line temperature
Example scenario

HVAC superheat and subcooling worksheet

°C / °F
C
Tsl
12 °
Tssat
5 °
Tlsat
42 °
Tll
35 °
Result
SH: 7 K; SC: 7 K

Frequently asked questions

Does this determine the correct refrigerant charge?

No. It only computes measured differences; compare them with the equipment manufacturer’s procedure.

Where does my data go?

Calculations run on your device. Form inputs are not sent to a server.

Terms and definitions

Enter your values

Measurement system

The initial choice follows your browser region. Your choice is remembered on this device. Gallons are US gallons. Switching units keeps your numbers unchanged and interprets them in the new unit.

Numbers stay unchanged. Check the new unit and enter the intended measurement, or select an example for that system.

°C / °F

Choose the mode that matches the data you entered.

Options: C · F

Tsl

Measured suction-line temperature

Enter an absolute temperature, not a temperature rise. Use the unit shown beside this field. °C / °F

Minimum: -200 · Maximum: 1000 °C

Tssat

Suction saturation temperature from the correct pressure and refrigerant reference

Enter an absolute temperature, not a temperature rise. Use the unit shown beside this field. °C / °F

Minimum: -200 · Maximum: 1000 °C

Tlsat

Liquid saturation temperature from the correct pressure and refrigerant reference

Enter an absolute temperature, not a temperature rise. Use the unit shown beside this field. °C / °F

Minimum: -200 · Maximum: 1000 °C

Tll

Measured liquid-line temperature

Enter an absolute temperature, not a temperature rise. Use the unit shown beside this field. °C / °F

Minimum: -200 · Maximum: 1000 °C

Result

Result

Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature. No refrigerant lookup or charge diagnosis is made.

Calculated from your entries using the method below.

SH

Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature. No refrigerant lookup or charge diagnosis is made.

Calculated from your entries using the method below.

SC

Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature. No refrigerant lookup or charge diagnosis is made.

Calculated from your entries using the method below.

Value

Superheat is suction-line minus suction saturation; subcooling is liquid saturation minus liquid-line temperature. No refrigerant lookup or charge diagnosis is made.

Calculated from your entries using the method below.

Common mistakes and quick fixes

Tsl · Tssat · Tlsat

Mistake: Changing units and assuming the entered numbers were converted.

Fix: Numbers stay unchanged. Check the new unit and enter the intended measurement, or select an example for that system.

Does this determine the correct refrigerant charge?

Mistake: Treating a result as valid outside the described scope.

Fix: No. It only computes measured differences; compare them with the equipment manufacturer’s procedure.

Limits and key assumptions

  • No. It only computes measured differences; compare them with the equipment manufacturer’s procedure.
  • No refrigerant lookup or charge diagnosis is made.
  • Displayed results may be rounded; rounding does not add measurement precision.